- Overview
- Customer Benefits
- Performance Characteristics
- Technical Data
- Accessories
- Download PDF
- Enquiry
Walk in Growth Chambers
The REMI Walk-in Growth Chambers are designed for precise monitoring of temperature, humidity and illumination conditions required for assistance of Seeds & plant growth.These chambers are available in standard or can be tailor made to suit specific requirements.
Advantages
- Maintains precise long term conditions
- Complete solution for simulation of desired Temperature & humidity in the chamber
- Proper illumination by fluorescent Tubes for assistance in growth
Features | Customer benefits | Characteristics |
Positive Air flow technology |
|
Constant circulation of air throughout the chamber achieves homogeneous Temperature & Humidity conditions. |
Humidifier system |
|
|
Humidity sensor |
|
|
Illumination system |
|
|
Cooling system |
|
|
Safety Features |
Audio-Visual alarm for temperature & humidity variations |
Float switch cuts off supply to heater in case of low water level in humidifier tank. |
Stand-by Cooling system & Humidity system |
|
|
PLC with color HMI |
|
|
Accessories and Services |
|
|
- Tailor made sizes as per available space.
- Microprocessor controlled refrigeration system & heaters provide temperature accuracy and reproducible results.
- Illumination by fluorescent tubes for assistance of plant growth.
- Temperature range 20 °C to 60 °C, Accuracy ± 1⁰C.
- Humidity range 40 % to 95 % RH,Accuracy ± 2% RH.
- User friendly LCD screen
- Easy-to-read large display.
- Integrated Data logger for large data storage.
- Variety of options for the graphic display of process parameters & utilities.
- Real time clock for proper data management.
- Electronically controlled humidification system with German humidity sensors.
- Sealed Toughened glass view window on door felicitates sample viewing.
- Temperature, Humidity and utility failures visual and audible alarms.
- Remi “DATASOFT” data monitoring software.
- Stainless steel racks and trays.
Walk in Growth Chambers |
WGC-50 |
WGC-80 |
WGC-100 |
WGC-120 |
WGC-150 |
Internal Volume (Liters) |
5000 |
8000 |
10000 |
12500 |
15000 |
Number of Shelves |
16 |
24 |
32 |
48 |
48 |
Internal Dimension W x D x H (mm) |
1250 x 2000 x 2000 |
2000 x 2000 x 2000 |
2000 x 2000 x 2500 |
2000 x 2500 x 2400 |
2500 x 2500 x 2400 |
External Dimension W x D x H (mm) |
1410 x 2950 x 2160 |
2160 x 2950 x 2160 |
2160 x 2950 x 2660 |
2160 x 3450 x 2560 |
2660 x 3450 x 2560 |
Sensor |
Capcitance type direct reading sensor | ||||
Temperature Range & Accuracy |
20°C to 60°C, ± 1°C | ||||
Humidity Range (Rh) & Accuracy |
40% to 95%, ± 3% RH | ||||
Audio Visuasl Variation Alarm |
Set Humidity ± 3% RH, Set Temperature ± 2°C | ||||
Internal Body Material |
Stainless Steel 304 grade (Standard Models), Stainless Steel 316 grade (GMP Models) |
||||
External Body Material |
Powder Coated CRCA Steel (Standard Models), Stainless Steel 304 grade (GMP Models) |
||||
Insulation |
80 mm minimum, CFC free polyurethane foam |
||||
Illumination |
Fluorescent Tubes |
||||
Control & Display |
Microprocessor based PID control system with large 4" LCD Display |
||||
Power Failure Alarm |
Audio Visual Alarm |
||||
Door Open Alarm |
Audio Alarm in case door open for over one minute |
||||
Electrical |
220-240 volts, 50Hz, Single Phase |
- PLC Based Control System with 7” colour HMI Touch Screen
- Software for Data acquisition.
- Data logger with 8 Capacitance type Sensors (4 Temperature + 4 Humidity)
- Standby Refrigeration System
- Standby Humidity System
- Magnetic Door Access Security System
- GSM Mobile Alert for six Numbers
- Stainless steel racks and trays.
- Validation [ mapping ] consist of one cycle for temperature and humidity at any one set point for 24 hours on empty and loaded condition of Walk-in Chambers